• Maximize productivity with the combined Fluke 289 and FlukeView forms combo kit. With built-in data logger and TrendCapture capability, the 289 helps you track down elusive, intermittent problems, monitoring equipment with any of its functions while you do other jobs. Overlay your logged data from six meters or six time periods to find cause and effect relationships or for condition monitoring applications in FVF software. Turn your data into meaningful graphs and tables for a professional report. The 289/FVF combo kit gives you a practical and affordable approach to predictive maintenance and is delivered with a soft case (C280).
    Read more
    • Precise laser technology for more accurate and repeatable measurements
    • Large, easy-to-read backlit LCD display for easy viewing
    • Small and lightweight design fits easily fits into your tool box
    • 8:1 distance to spot ratio
    • IP40 rated for extra protection
    • Displays the minimum, maximum or average temperature, or the difference between two measurements
    • Hi and Lo alarms for rapid display of measurements outside the limits
    • Powered by one (1) AA battery
    Read more
    • Bargraph to display insulation resistance.
    • Displays the value of external AC voltage along with flashing symbol.
    • Auto null function to automatically subtract the test lead resistance before displaying the real continuity resistance value.
    • Trac-Lok mode to conserve battery life on insulation and continuity tests. Live circuit warning beeper.
    • Releasing the test button automatically discharges the charges stored in the circuit under test. Backlight function to view the test results in dimly lit areas.
    • 200mA continuity measuring current to IEC 61557.
    • Minimum 1mA current on insulation tests to IEC 61557.
    Read more
  • • 3pole and 2pole Earth Resistance measurement (0.01Ω-2000Ω) • Waterproof design (IP67) • Rotary Switch makes the user interface very intuitive • Large LCD Display with Backlight • Led to monitor correct / non correct auxiliary earth spike resistance • Earth Voltage Measurement (AC/DC 0-300V) • CAT â…£ 100V

    • 3pole and 2pole Earth Resistance measurement (0.01Ω-2000Ω) • Waterproof design (IP67) • Rotary Switch makes the user interface very intuitive • Large LCD Display with Backlight • Led to monitor correct / non correct auxiliary earth spike resistance • Earth Voltage Measurement (AC/DC 0-300V) • CAT Ⅳ 100V
    • WP
    • Backlight
    • AutoPowerOff
    Read more
  • 6000 counts ■AC True RMS ■Data hold/Range hold ■Relative value measurement ■MAX/MIN value recording mode ■LCD with backlight ■Auto power save (15min.) (cancelable) ■Attachment body cover for protection ■EF (Electric Field) detection Display : numeral display 6000 Sampling rate : 5 times/sec.

    Read more
  • Dual display shows voltage/current and its frequency ■True RMS ■EF (Electric Field) sensing ■VFD (Variable Frequency Drive) frequency measurement ■Low input impedance voltage measurement capable of attenuating the effects of ghost voltage ■Data hold, Range hold ■Relative value ■Peak hold (5msec.) ■Auto Power Save (30min.) (cancelable) Sampling rate : approx. 5 times / sec

    Read more
  • One-shot or continuous measurement push switch ■DCV measurement range (DC60V) ■Auto discharge function ■Inner battery check range ■ACV measurement range ■Shoulder Strap

    Read more
  • Sanwa KS1 3-Phase Detector Fitur: * Detektor 3-fasa * Phase sequence dan open phase check * Klip jepit buaya berukuran besar

    Read more
  • Sanwa MG5000 High Voltage Insulation Tester (5kV)

    Fitur: * Tes tegangan DC 5000V/2500V/1000V/500V/250V * Resistansi insulasi sampai dengan 1T * Arus short circuit hingga 4mA * Fitur Dielectric Absorption Ratio (DAR) * Fitur Polarisation Index (PI) * Fungsi auto discharge * Fitur data hold (otomatis) * Fitur auto power save: unit akan otomatis off setelah 10 miunutes tidak digunakan * Standar keamanan CAT IV.600V * Standar IP54

    Read more
  • 4 digits 9999 count & 3-5/6 digits 6000 count ■AC True RMS ■Dual display with backlight ■Automatic measurement for ACV/DCV/Ω under  low impedance ■High speed bar graph ■Capacitance measurement ※Not suitable for measurement of condensers with large leak current.â– K type temperature -50℃〜1000℃ ※Optional accessory K-AD is necessary. ※K type temp. sensor K-250PC is included as a standard accessory. ■Frequency measurement (AC sine wave only) ■Logic frequency measurement, duty cycle measurement ■Conductance measurement ■MAX, MIN, MAX-MIN recording mode ■Capture (peak hold) 1ms in duration ■Data hold, Range hold ■Relative value ■Auto power saving mode (30min.) (cancelable) ■Optical Link USB interface (optional) Data Logging Mode ■87,328 data points in built-in memory (single display) 43,664 data points in built-in memory (dual display) ■Selection of measurement interval 0.05s/0.1s/0.5s/1s/2s/3s/4s/5s/10s/15s/30s/ 60s/120s/180s/300s/600s ■Auto-standby mode when a sampling speed of 30s or longer is selected ■Export logged data to PC ※Optional accessory KB-USB7 and PC Link7 are necessary. Display : numeral display 9999 & 6000, bar graph 41 segments Sampling rate : 5 times/sec., 60 times/sec. for bar graph Max.EN61326-1:2006 ■Battery life : Approx. 100h (alkaline battery) at DCV range

    Read more